4te3r3r 发表于 2014-11-25 08:47:04

Radware 8016风扇告警

机房巡检,两台Radware 8016面板上的FAN只指示灯亮红灯。如何确认是否是风扇硬件故障?一、开启告警日志实时弹出
#manage terminal traps-output set 2(或on)
HNCS-PC-IDC-SSL02-8018#24-11-2014 09:31:47 WARNING Fan failure was detected. 1 fan is not operational
二、开启日志记录
#manage trap-logging status set 1      /*开启日志记录
#manage trap-logging file-size set 1000
#manage trap-logging view-log            /*查看日志
#manage trap-logging clear-log            /*清除日志
HNCS-PC-IDC-SSL02-8018#manage trap-logging view-log
14452         warning         Fan failure   24-11-2014      1.3.6.1.4.1.89.
                                          was detected.   04:51:47      7            
                                          1 fan is not                                 
                                          operational
三、查看风扇的工作状态
#system internal fans                                          


页: [1]
查看完整版本: Radware 8016风扇告警