虚拟机vMotion失败:Ageneral system error occurred:Failed to flush check...
Ø问题描述: 1、vMotion虚拟机失败后,系统提示如下错误提示:A general system error occurred:Failed to flush checkpoint data!
复制代码
2、发生上述问题时,vm有如下设定: 虚拟机的分辨率大于1280x1024;
虚拟机选用了WDDM驱动(Windows 7、Windows Server 2008R2);
虚拟机选用的硬件版本为8; 3、vCenter Server的错误信息提示里有如下内容: An I/O erroroccurred while savingthe checkpoint:0(Resource tempoarily unavailable);
Failed to write checkpoint data(offset xxxxxxxx,size xxxx):Failed to resume VM; 4、在虚拟机的vmware.log里有类是如下错误信息:
vmx| MigrateSetState: Transitioning from state 9 to 11. vmx|Migrate_SetFailure: Failed waiting for data.Error bad0006. Limitexceeded. vmx| vmx| Migrate:cleaning up migration state. vmx|MigrateSetState: Transitioning from state 11 to 0. vmx| Msg_Post:Error vmx| vMotion migration failed. The checkpoint data length (xxxxx bytes) or the offset (xxxxxxxx bytes)exceeds the maximum checkpoint data length (xxxxxxxx byte). vmx| Module Migrate power on failed.
Ø故障分析 :
确认虚拟机硬件版本为8的WDDM驱动所包含的新组件,vMotion对于显存要求有所增加。缺省分配的缓存对于系统要求而言,较小。但是如果mks.enable3d值被设定为FALSE,则系统缓存尺寸不会自动跟随新组件需求增加而增加; Ø 解决方案:解决这个问题需要执行如下步骤:
1、在执行vMotion之前,先将虚拟机的分辨率调整小于1280x1024; 2、暂时不要将虚拟机的硬件版本升级到8; 3、增加基础checkpoint cache size的值,将它从8MB从16MB(16777216byte)以便能满足单一显示器的分辨率。如果使用2个1600x1200分辨率的显示器,则需要将显存增加到20MB(20971520byte)。
备注:如果不想关闭VM可以通过在/etc/vmware/config文件里添加上述参数; 将mks.enable3d值设定为TRUE。
感谢楼主~学习了~~