zabbix通过snmp来监控dell的idrac
zabbix通过snmp来监控dell的idrac20160726
原作来自zabbix论坛,改进版来自后附github的地址,本地是整理后的版本,增加了value mapping的内容,已经作为README的更新提交给作者。
模版请查看附件,或者去github下载。
Menu: Administration->General->Value mapping->Create value map
CONFIGURATION OF VALUE MAPPING
notice:
1) use Template_Dell_iDRAC_SNMPv2.zbx.xml
2) website: https://github.com/endersonmaia/zabbix-templates/tree/master/dell/idrac
add k/v(s) as given below:
--------------------------
DellDracDiskState
1 -> Unknown
2 -> Ready
3 -> Online
4 -> Foreign
5 -> Offline
6 -> Blocked
7 -> Failed
8 -> Non-RAID
9 -> Removed
Dell iDRAC Network Device Connection Status
1 -> Down
2 -> Up
Dell Open Manage System Status
1 -> Other
2 -> Unknown
3 -> OK
4 -> NonCritical
5 -> Critical
6 -> NonRecoverable
DellPowerState
1 -> Other
2 -> Unknown
3 -> Off
4 -> On
Dell PSU State Settings
1 -> Unknown
2 -> Online (state disabled)
4 -> not Ready
8 -> Fan Failure
10 -> Online and Fan Failure
16 -> On
242 -> Online and OK
DellRaidLevel
1 -> Unknown
2 -> RAID-0
3 -> RAID-1
4 -> RAID-5
5 -> RAID-6
6 -> RAID-10
7 -> RAID-50
8 -> RAID-60
9 -> Concatenated RAID 1
10 -> Concatenated RAID 5
DellRaidVolumeState
1 -> Unknown
2 -> Online
3 -> Failed
4 -> Degraded
Dell_PSU_SensorState
1 -> Presence Detected
2 -> PS Failure
4 -> Predictuve Failure
8 -> PS AC lost
16 -> AC lost or out of range
32 -> AC out of range but still present
--------------------------
附件:http://down.运维网.com/data/2366145